Major operational problems in distillation column due to adverse vapour flow conditions can cause
  • foaming
  • entrainment
  • weeping/dumping
  • flooding
Foaming
                Foaming refers to the expansion of liquid due to passage of vapour or gas. Although it provides high interfacial liquid-vapour contact, excessive foaming often leads to liquid buildup on trays. In some cases, foaming may be so bad that the foam mixes with liquid on the tray above. Whether foaming will occur depends primarily on physical properties of the liquid mixtures, but is sometimes due to tray designs and condition. Whatever the cause, separation efficiency is always reduced.

Entrainment
                      Entrainment refers to the liquid carried by vapour up to the tray above and is again caused by high vapour flow rates. It is detrimental because tray efficiency is reduced: lower volatile material is carried to a plate holding liquid of higher volatility. It could also contaminate high purity distillate. Excessive entrainment can lead to flooding.

Weeping/Dumping
                                This phenomenon is caused by low vapour flow. The pressure exerted by the vapour is insufficient to hold up the liquid on the tray. Therefore, liquid starts to leak through perforations. Excessive weeping will lead to dumping. That is the liquid on all trays will crash (dump) through to the base of the column (via a domino effect) and the column will have to be re-started. Weeping is indicated by a sharp pressure drop in the column and reduced separation efficiency.

Flooding
               Flooding is brought about by excessive vapour flow, causing liquid to be entrained in the vapour up the column. The increased pressure from excessive vapour also backs up the liquid in the downcomer, causing an increase in liquid holdup on the plate above.  Depending on the degree of flooding, the maximum capacity of the column may be severely reduced. Flooding is detected by sharp increases in column differential pressure and significant decrease in separation efficiency.